TVOC® – ATEX Certified Fixed VOC Detector

Total VOC Detector for Continuous Volatile Organic Compound Monitoring

TVOC-1aMODTVOC is a fixed continuous VOC detector for the detection and measurement of total volatile organic compounds (VOCs). Its photoionisation detection (PID) capabilities utilise advanced patented Fence Electrode technology, a 3 electrode format with increased resistance to humidity and contamination.

A robust fixed VOC detector, TVOC has a selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm and is ideal for use in manufacturing and process industries where VOCs are typically present.

With a 4-20 mA analogue output, the TVOC VOC detector can be simply integrated into a DCS control system to provide warnings and enable control of high VOC levels in the working environment.

ATEX approvals enable a 3 wire TVOC system to be used in Zone 2 hazardous areas, without safety barriers. ATEX and IECEx approvals allow TVOC to be used in Zone 1 hazardous areas, with safety barriers.

The TVOC fixed VOC detector utilises a diffusive sample technique resulting in less contamination issues compared to pumped systems, reducing lamp cleaning and servicing requirements. Simple to install service and calibrate, TVOC requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.

The TVOC fixed VOC detector is also available for use with a pumped system for applications where sample conditioning is required.

TVOC is part of a range of VOC detectors that includes the hand held PhoCheck Tiger, PhoCheck+ and FirstCheck+ instruments.

Features

  • Independently verified as best performing PID technology
  • Patented Fence Electrode Technology for fast, accurate humidity resistant operation
  • ATEX: Zone 2 hazardous areas without safety barriers (3 wire option)
  • ATEX & IECEx: Zone 1 hazardous areas with safety barriers (4 wire option)
  • 3 wire option allows direct replacement of an existing PID area monitor (Zone 2 ATEX)
  • Selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm
  • Diffusive monitoring – no pump required
  • Scaled 4-20 mA analogue output
  • Includes a 10.6 eV lamp
  • Easy access PID sensor allows simple servicing
  • Simple calibration procedure

Specification

SENSOR (PID)
10.6 eV lamp with Ion Science patented Fence Electrode technology*

HAZARDOUS AREA SAFETY APPROVALS
ATEX:   II 3G Ex nA IIC T4 (-40°C ≤Ta ≤ 50°C)
IECEX:  Ex ia IIC T4 (-20°C ≤Ta ≤ 50°C)

INGRESS PROTECTION RATING
IP65 – dependent on cable glands fitted Sensor – IP53

POWER
5-28 VDC Max 65 mA

OUTPUT
4-20 mA (requires a 8-35 VDC power supply)
For IS requirements 8-30 VDC power supply

RANGE
0-10 ppm, 0-100 ppm, 0-1000 ppm User selectable

SAMPLING
Diffusion (can be pumped if required using an adaptor)

DISPLAY
7 segment, 4 digit LCD, 4 color LEDs

RESPONSE
Sensor – T90 < 5 sec.  Detector – 1 minute as standard**

ACCURACY
0-100ppm +/- 1ppm or >98%, 100-1000ppm +/- 2ppm or >75%

LINEARITY
0-1000ppm > 75%

CALIBRATION
Magnetically accessed 100 ppm Isobutylene via calibration kit accessory

TEMPERATURE
Operating: -20 to 50 oC (-4 – 122 oF) Humidity: 0-95% RH
(non- condensing)

WEIGHT & DIMENSIONS 
Instrument: 1.4 kg (3.1 lb) Packed: 1.6 kg (3.5 lb)  Dimensions: 188 x 126 x 78 mm (7.4 x 4.9 x 3”)

NB: All specifications are against an isobutylene calibration at 20 °C, 90% RH and up to 100 ppm.

+ Overview

TVOC® – ATEX Certified Fixed VOC Detector

Total VOC Detector for Continuous Volatile Organic Compound Monitoring

TVOC-1aMODTVOC is a fixed continuous VOC detector for the detection and measurement of total volatile organic compounds (VOCs). Its photoionisation detection (PID) capabilities utilise advanced patented Fence Electrode technology, a 3 electrode format with increased resistance to humidity and contamination.

A robust fixed VOC detector, TVOC has a selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm and is ideal for use in manufacturing and process industries where VOCs are typically present.

With a 4-20 mA analogue output, the TVOC VOC detector can be simply integrated into a DCS control system to provide warnings and enable control of high VOC levels in the working environment.

ATEX approvals enable a 3 wire TVOC system to be used in Zone 2 hazardous areas, without safety barriers. ATEX and IECEx approvals allow TVOC to be used in Zone 1 hazardous areas, with safety barriers.

The TVOC fixed VOC detector utilises a diffusive sample technique resulting in less contamination issues compared to pumped systems, reducing lamp cleaning and servicing requirements. Simple to install service and calibrate, TVOC requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.

The TVOC fixed VOC detector is also available for use with a pumped system for applications where sample conditioning is required.

TVOC is part of a range of VOC detectors that includes the hand held PhoCheck Tiger, PhoCheck+ and FirstCheck+ instruments.

+ Feature

Features

  • Independently verified as best performing PID technology
  • Patented Fence Electrode Technology for fast, accurate humidity resistant operation
  • ATEX: Zone 2 hazardous areas without safety barriers (3 wire option)
  • ATEX & IECEx: Zone 1 hazardous areas with safety barriers (4 wire option)
  • 3 wire option allows direct replacement of an existing PID area monitor (Zone 2 ATEX)
  • Selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm
  • Diffusive monitoring – no pump required
  • Scaled 4-20 mA analogue output
  • Includes a 10.6 eV lamp
  • Easy access PID sensor allows simple servicing
  • Simple calibration procedure
+ Specification

Specification

SENSOR (PID)
10.6 eV lamp with Ion Science patented Fence Electrode technology*

HAZARDOUS AREA SAFETY APPROVALS
ATEX:   II 3G Ex nA IIC T4 (-40°C ≤Ta ≤ 50°C)
IECEX:  Ex ia IIC T4 (-20°C ≤Ta ≤ 50°C)

INGRESS PROTECTION RATING
IP65 – dependent on cable glands fitted Sensor – IP53

POWER
5-28 VDC Max 65 mA

OUTPUT
4-20 mA (requires a 8-35 VDC power supply)
For IS requirements 8-30 VDC power supply

RANGE
0-10 ppm, 0-100 ppm, 0-1000 ppm User selectable

SAMPLING
Diffusion (can be pumped if required using an adaptor)

DISPLAY
7 segment, 4 digit LCD, 4 color LEDs

RESPONSE
Sensor – T90 < 5 sec.  Detector – 1 minute as standard**

ACCURACY
0-100ppm +/- 1ppm or >98%, 100-1000ppm +/- 2ppm or >75%

LINEARITY
0-1000ppm > 75%

CALIBRATION
Magnetically accessed 100 ppm Isobutylene via calibration kit accessory

TEMPERATURE
Operating: -20 to 50 oC (-4 – 122 oF) Humidity: 0-95% RH
(non- condensing)

WEIGHT & DIMENSIONS 
Instrument: 1.4 kg (3.1 lb) Packed: 1.6 kg (3.5 lb)  Dimensions: 188 x 126 x 78 mm (7.4 x 4.9 x 3”)

NB: All specifications are against an isobutylene calibration at 20 °C, 90% RH and up to 100 ppm.